In order to have your laser perform at an optimal level you need to perform following maintenance guidelines:
LASER CUTTER | |||
Component | Task | By | Max. Interval |
Secondary Mirror | Clean | End User | 1 Day or 8 Hours |
Head Mirror | Clean | End User | 1 Day or 8 Hours |
Head Lens | Clean | End User | 1 Day or 8 Hours |
Nozzle | Clean | End User | 1 Day or 8 Hours |
Airflow Nozzle | Check | End User | 1 Day or 8 Hours |
Primary Mirror | Clean | End User | 1 Week or 40 Hours |
Nozzle Height | Check | End User | 1 Week or 40 Hours |
Conveyor Planks | Check/Clean | End User | 1 Week or 40 Hours |
Air Filters | Clean/Replace | End User | 1 Month or 170 Hours |
Emergency Stops | Check | End User | 1 Month or 170 Hours |
X-Axis Movement | Check/Clean | End User | 1 Month or 170 Hours |
Y-Axis Movement | Check/Clean | End User | 1 Month or 170 Hours |
All Rails | Clean and Lubricate | End User | 1 Month or 170 Hours |
X-Belt Tension | Check/Adjust | Dealer | 1 Year or 2000 Hours |
Y-Belts Tension | Check/Adjust | Dealer | 1 Year or 2000 Hours |
X-Motor Belt Tension | Check/Adjust | Dealer | 1 Year or 2000 Hours |
Y-Motors Belt Tension | Check/Adjust | Dealer | 1 Year or 2000 Hours |
Laser Beam Alignment | Check | Dealer | 1 Year or 2000 Hours |
Overall Machine Service | Check | Dealer | 1 Year or 2000 Hours |
All Optics | Replace | Dealer | 2 Years or 4000 Hours |
Reprocess Laser Unit | Reprocess | Dealer | 15 - 20K hours |
WATER-COOLED LASER | |||
Component | Task | By | Interval |
Chiller Water Level | Check | End User | 1 Week or 40 Hours |
Chiller Water Quality | Check | End User | 1 Week or 40 Hours |
Chiller Water Pipes | Check | End User | 4 Weeks or 120 Hours |
Chiller Air Filter | Clean | End User | 4 Weeks or 120 Hours |
Chiller Water | Replace | End User | 6 Months or 1000 Hours |
Chiller Service | Service | Local ICS Dealer | 1 Year or 2000 Hours |
AIR-COOLED LASER | |||
Component | Task | By | Interval |
Laser Unit Fans | Clean | End User | 4 Weeks or 120 Hours |
EXTRACTION SYSTEMS | |||
Component | Task | By | Interval |
Extraction Hoses | Clean | End User | 2 Weeks or 80 Hours |
Extraction Fan | Clean | End User | 4 Weeks or 120 Hours |
Extraction Fan Inside | Clean | Dealer | 6 Months or 1000 Hours |
Vacuum Chamber | Clean | Dealer | 1 Year or 2000 Hours |
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article